Kromat Corporation
1200 Florence-Columbus Road,
Bordentown, NJ 08505,
United States
ph: (856) 220-7060
fax: (856) 457-3053
info
PC Series Capillary Gas Chromatography columns
Perfected Capillary (PC) series is our newly improved line of GC columns engineered through validated manufacturing processes. Kromat chemists have created proprietary polysiloxane technologies to synthesize our own high quality stationary phases. Careful selection of the raw materials, validated reaction controls and exhausting fractionations ensure desired stationary phase properties for exceptional thermal stability. Tedious coating, deactivation, and bonding processes give very low bleed GC columns. Every column is individually tested to pass the stringent quality control specifications.
High quality fused silica tubing, stable to 400°C
Proprietary tedious tubing deactivation processes, inert with proper surface wettibility
Innovative Stationary Phase Chemistry, stationary phases synthesized in our own laoratory
Low bleed MS phases, arylene chemistry
PC column catalog numbering system:
For a PC column of
Stationary phase SP (Table A)
Column Length CL (Table B)
Column Diameter CD (Table C)
Film Thickness FT (Table D)
the catalog number is:
SP CL CD FT
For example, the catalog number for PC-1701, 30m X 0.32mm X 0.5 µm is 5530315.
the catalog number for PC-5MS, 60m X 0.25mm X 0.25 µm is 4660212.
Table C | |
Column Diameter, mm | CD |
0.25 | 2 |
0.32 | 3 |
0.53 | 5 |
Table A | |
Stationary Phase | SP |
PC-1 | 40 |
PC-1MS | 42 |
PC-5 | 44 |
PC-5MS | 46 |
PC-35 | 48 |
PC-50 | 50 |
PC-1301 | 53 |
PC-1701 | 55 |
PC-WAX | 56 |
PC-AWAX | 57 |
PC-BWAX | 58 |
PC-225 | 60 |
PC-200 | 62 |
PC-PONA | 64 |
PC-VOC | 66 |
PC-624 | 68 |
PC-2887 | 69 |
PC-2340 | 70 |
PC-AL2O3/S | 72 |
PC-Molesieve 5A | 75 |
PC-PLOT Q | 77 |
PC-PLOT U | 78 |
PC-PONA | 80 |
Table D | |
Film Thickness, µm | FT |
0.10 | 10 |
0.20 | 11 |
0.25 | 12 |
0.33 | 13 |
0.40 | 14 |
0.50 | 15 |
0.88 | 16 |
1.00 | 17 |
1.40 | 18 |
1.50 | 19 |
1.80 | 20 |
2.00 | 21 |
2.65 | 22 |
3.0 | 23 |
4.0 | 24 |
5.0 | 25 |
10.00 | 26 |
15.00 | 27 |
20.00 | 28 |
25.00 | 29 |
30.00 | 30 |
40.00 | 31 |
50.00 | 32 |
Table B | |
Column Length, m | CL |
10 | 10 |
15 | 15 |
20 | 20 |
25 | 25 |
30 | 30 |
50 | 50 |
60 | 60 |
90 | 90 |
100 | 00 |
Nonpolar general purpose phase for chemical solvents and impurities, gases, sulfur compounds, essential oils, hydrocarbons, volatiles and semivolatiles, pesticides, oxygenates.
Temperature range: -60°C to 350°C.
USP G1, G2, G38 phases
PC-1MS is GC/MS certified phase designed for sensitive low-bleeding GC/MS applications.
Nonpolar general purpose phase for phamarceutical applications, solvents and impurities, pesticides, hydrocarbons, PCBs and PBBDEs essential oils, volatiles and semivolatiles
Temperature range: -60°C to 350°C.
USP G27 and G36 phases
The 5% diphenyl/95% dimethyl polysiloxane stationary phase is the most popular GC stationary phase and is used in a wide variety of applications. PC-5 is the first attempt for a new application where no published or any other information is available.
PC-5MS is GC/MS certified phase with equivalent 5%diphenyl95%dimethyl silphenylene chemistry. It is designed for sensitive low-bleeding GC/MS applications.
General purpose columns for organochlorine pesticides, PCBs and PBDPEs, herbicides, pharmaceuticals
Temperature range: 40°C to 320°C
USP G42 phase
Popular phase for pesticides and herbicides, confirmational to PC-5 and PC-1701 phases.
General purpose columns for pesticides, herbicides, rosin acids, phthalate esters, triglycerides, sterols
Temperature range: 40°C to 320°C
USP G3 phase
The high phenyl content gives selectivities with elution order and retention time changes useful for many unique applications, such as in pesticides and herbicides.
Application-specific columns for volatile organic pollutants. Recommended in US EPA methods for volatile organic pollutants
Temperature range: -20°C to 240°C
USP G43 phase
Ideal polarity for analyzing volatile organic pollutants in EPA Methods 8260 and 524.2. Confirmational phase to PC-Volatiles.
General purpose columns for alcohols, oxygenates, PCB congeners or (e.g.) Aroclor mixes, pesticides
Temperature range: -20°C to 280°C
USP G46 phase
The most popular stationary phases for chemical solvents and impurities, pharnmaceutical applications, general chemical analysis, evironmantal applications, pesticides and herbicides.
General purpose columns for residual solvents, alcohols, oxygenates, and volatile organic compounds
Temperature range: -20°C to 280°C
USP G43 phase
Many analysts feel the Rtx®-1301 column has the best cyanosilicone bonded stationary phase available, with no other column manufacturer providing lower bleed, longer lifetime, or better inertness. Our polymer is fully characterized to ensure long-term reproducibility, column-to-column consistency, and low bleed--even with sensitive detectors such as ECDs and MSDs
General purpose columns for FAMEs, carbohydrates, flavor compounds
Temperature range: 40°C to 240°C
USP G7, G19 phases
Unique polarity slightly less polar than Wax phases and can be used for many of the same applications.
General purpose columns for solvents, fluorocarbons, alcohols, ketones, glycols. phenols, nitrosamines, organochlorine pesticides, chlorinated hydrocarbons, and chlorophenoxy herbicides
Temperature range: -20°C to 340°C
USP G6 phase
Capable of many difficult separations not possible on any other bonded stationary phase. unique selectivity that changes elution orders and resolves compounds that phenyl, cyano, or wax phases can not.
Unique selectivity for volatile organic pollutants, such as trihalomethanes, light hydrocarbons and aromatics specified in US EPA Method 502.2 and in many gasoline range methods for UST monitoring
Stable to 270°C
Able to resolve and all compounds listed in US EPA methods 502.2 or 524.2, a 105-meter column can separate the light gases specified in EPA methods without subambient cooling. Narrow bore columns can interface directly in GC/MS systems
Organochlorine pesticides and herbicides.
ideal for GC/ECD or GC/MS analyses
Stable to 340°C
Improved resolution and faster analyses over 1701 or phenyl phases. overcomes the coelutions and analyte breakdown typically encountered in chlorinated pesticide analyses for EPA Methods 8081, 608, and CLP.
Phasess for organochlorine pesticides and herbicide
Stable to 330°C
Organochlorine pesticides specific columns.
Confirmational phasess to PC-Pesticides A and B for pesticides and herbicide, designed for EPA 608
Stable to 330°C
Complementary to PC-A and B columns for applications of pesticides and herbicide
Polar columns for FAMEs, solvents, BTEX aromatics, flavor compounds, alcohols
Temperature range: 20°C to 260°C
USP G14, G15, G16, G20, G39 phases
Chemically bonded PEG for improved thermal stability, Inertness and efficiencicy.
Acidified PEG columns for caboxylic acids as well as FAMEs, solvents, BTEX aromatics, flavor compounds, alcohols
Temperature range: 40°C to 250°C
USP G25, G35 phases, FFAP equivalent phase
Chemically bonded PEG for improved thermal stability, Inertness and efficiencicy, equivalent to other FFAP phases.
Base modified PEG columns for basic compounds containing amines
Temperature range: 40°C to 220°C
Chemically bonded PEG for improved base analysis.
Molecular Sieve 5A Porous Layer Open Tubular PLOT
Stable to 350°C
Designed for efficient separation of permanent gases includoing Ar/O2, CH4, C2H6, and CO at ambient temperature or above, excellent choice for rapid separation of permanent gases and light hydrocarns in refinery or natural gases
Immobilized and deactivated aluminium oxide PLOT
Stable to 200°C
Highly selective for C1-C5 hydrocarbons, separates all unsaturated hydrocarbon isomers above ambient temperatures.
Polystyrene-divinylbenzene porous polymer, Nonpolar PLOT
Stable to 320°C
Excellent for analysis of solvents, light hydrocarns of C1 to C3 isomers and alkanes up to C12, useful in analysing CO2
Proprietary polar porous polymer, polar PLOT
Stable to 290°C
Confirmational columns to PC-Q PLOT in applications of solvents, light hydrocarbons to C10, useful in analysing CO2